Section 14-02B: Generator and Regulator, External Fan Type, 215 Ampere | 1996 F-Super Duty Equipped with 7.3L Diesel Engine Workshop Manual |
NOTE: For abnormal noise and excessive end play, it is more effective to inspect components with the generator assembled. The generator bearings are part of the front generator assembly. Do not try to replace them separately.
NOTE: Do not apply grease or lubricant. Generator comes prelubricated. Wipe off all grease completely. Use compressed air and blow any loose debris from generator components.
CAUTION: Do not clean generator parts with solvent.
Clean the generator front bearing with a clean cloth.
Rotate the generator front bearing on the drive end of the rotor shaft.
Check for any scraping noise, looseness or roughness. Inspect for excessive lubricant leakage. If any of these conditions exist, replace damaged components.
Inspect generator pulley and fan assembly.
Check for excessive looseness on the rotor shaft. Inspect for cracks, bent or damaged fins, or damaged pulley. Replace generator pulley and fan assembly if any of the above conditions exist.
Inspect front and rear generator housings.
Check for cracks or damage, especially in the areas of assembly ears and mounting posts. Replace any components that show damage.